EMAIL: sales@andalanprimasejahtera.com TELP 021-29253187 , 021-29253184 FAX 021-29253186
Thursday, 18 February 2016
Wednesday, 17 February 2016
Sunday, 14 February 2016
K28000 Tank Car Gauging Pole
K28000 Tank Car Gauging Pole |
Features and Benefits • Meets ASTM D1085 specifications • 36" or 32 1/8" in length, with 1/8" graduations |
![]() | Ordering Information | ||||||
|
K27851 LPG Sample Containers
K27851 LPG Sample Containers |
LPG Sample Containers Welded stainless steel cylinders for obtaining representative samples of liquefied petroleum (LP) gases. Two-valve type (1/4 IPS), with 20% outage tube and built-in pressure relief valve factory preset between 540 to 600psi (38-42 kg/cm2). |
![]() | Ordering Information | ||||||||||||
|
K27600 Weighted Beaker
K27600 Weighted Beaker |
Weighted Beaker For beaker sampling from tank cars, tank trucks, shore tanks, ship tanks and barge tanks. Copper or stainless steel construction with weighted bottom. Includes handle and chained cork. Takes all level samples, running samples, and top, upper, middle, lower and outlet samples. Select 3/4" (19mm) opening for light crude oils, light lubricating oils, kerosenes, gasolines, transparent gas oils, diesel fuels, and distillates, or 1 1/2" (38mm) for heavy crude and fuel oils, heavy lubricating oils and nontransparent gas oils. Shipping Information Shipping Weight: 6 lbs (2.7kg) |
![]() | Ordering Information | ||||||||
|
K27400 Drum Thief (Sampling Tube)
K27400 Drum Thief (Sampling Tube) |
![]() | Ordering Information | ||||||
|
K27700 Sample Thief (Bacon Bomb)
K27700 Sample Thief (Bacon Bomb) |
Sample Thief (Bacon Bomb) Obtains samples from storage tanks, tank cars and drums. When the thief strikes the bottom of the tank, a plunger assembly opens to admit the sample. The plunger closes again when the bomb is withdrawn, forming a tight seal. Samples can be taken at any depth with the use of a secondary trip line, or extension rods may be added for obtaining samples at levels of up to 18 (46cm) off the bottom. Equipped with plunger locking cam for tight closure during transport (except for 4 oz 1 1/8" dia. model). Special models include a 4 oz (118mL) ‘pencil’ model for sampling through small diameter pipes and openings, and clear acrylic samplers with plated brass plunger and end pieces. Modified samplers can be supplied for special applications – we invite your inquiries. |
![]() | Ordering Information - Sample Thief | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
![]() | K277-EXT Sample Thief Extension Rods |
Sample Thief Extension Rods Installs in sample thief plunger assembly. Stainless steel with threaded end. |
![]() | Ordering Information - Sample Thief Extension Rods | |||||||||||||||||||||||||||||
|
![]() | K27800 All-Levels Sample Thief |
All-Levels Sample Thief Similar to the standard 16 oz (473mL) Sample Thief (Bacon Bomb), but equipped with an adjustable needle valve opening instead of a plunger to control rate of flow during ‘all-levels’ and ‘running’ sampling from storage tanks. Plated brass construction. |
![]() | Ordering Information - All-Levels Sample Thief | ||||
|
![]() | K27900 Adjustable-Level Sample Thief |
Adjustable-Level Sample Thief Similar to the standard 16 oz (473mL) Sample Thief (Bacon Bomb), but equipped with an adjustable needle valve opening instead of a plunger to control rate of flow during ‘all-levels’ and ‘running’ sampling from storage tanks. Plated brass construction. |
![]() | Ordering Information - Adjustable-Level Sample Thief | ||||
|
K90375 Volumetric Karl Fischer Titrator
K90375 Volumetric Karl Fischer Titrator |
SpecificationsConforms to the specifications of: ASTM D789, D803, D890, D1123, D1152, D1193, D1348, D1364, D1568, D1631, D2072, D2575, D3401, D4017, D4377, D4672, D5460, D5530, E180, E203 Non-volatile memory: Up to 10 titration programs, Clock/calendar, Header texts: 2 lines x 40 characters Name of up to 4 operators Program comments: 8 lines x 40 characters Up to 55 results stored in Data Logger Languages: English Spanish, French, Latin Display: Graphic backlit LCD, 128 x 64 dots Keypad: Membrane, 7 keys, guaranteed up to 6 million strokes per key Material: PET with protective treatment Measuring ranges: From 0.1 mg up to 100% water Syringe volume: Standard syringe 5mL Resolution: 1/40000 of syringe volume Dispensing accuracy: (as relative error) ≤0.2% for volumes higher than 10% of the syringe Dispensing reproducibility: ±0.1% for volumes higher than 10% of the syringe Liquid contact materials: Syringe: borosilicate glass and PTFE Electovalve: PTFE and KEL-F Tubes: PTFE Inputs and outputs: Polarized electrode, BNC connector For external keyboard, miniDIN connector RS232C bidirectional for PC or printer, telephone connector RS232C for balance, telephone connector Stirrer control: On/Off and speed, RCA connector Electrical Requirements: 90-264VAC, 47-63 Hz, 24V DC Electrical safety: Meets EC, EN61010 EMC: Meets EC, EN 50081-2 and EN 50082-2 Permitted temperatures: Operating: 15-40°C Storage: -10-50°C ≤≥<80%, relative humidity, non-condensing Enclosure: ABS and enameled steel Included Accessories Power supply 90-264VAC, 47-63Hz, 24 V DC TLL SL syringe, 5mL (2) Burette inlet tube with bottle cap, DIN 45 screw (2) Burette outlet tube with antidiffuser device (2) Drier cartridge with molecular sieve (5) Inlet pump tube (for solvent dispensing) with bottle cap DIN 45 screw Inlet & Outlet tubes with conical adapter (2) Outlet pump tube with bottle cap DIN 45 screw Support for electrode & tubes with magnetic stirrer and vessel Double platinum electrode Electrode cable with BNC connector Pack (10) white O-rings Dimensions wxdxh,in.(cm) 5-1/4x6-1/2x12(130x160x300) Net Weight: 9 lbs. (4 kg) |
![]() | Ordering Information | ||||
|
![]() | Accessories | ||||||||||
|
K90365 Coulometric Karl Fischer Titrator
K90365 Coulometric Karl Fischer Titrator |
K90365 Coulometric Karl Fischer Titrator The K90365 offers new standards in versatility and ease of operation. Providing fast, accurate and reproducible determinations of water content in liquids, gases and powders. This easy to use titrator incorporates many state-of-the-art features. Designed to be equally suitable for meeting the routine needs of the Quality Control laboratory or the more demanding and varied requirements of research applications. Hard copies of results are provided by the built in high-speed thermal printer, along with statistics, data input parameters, sample ID numbers and time/date of analysis. At the heart of the K90365 is state of the art ACE (Automatically Compensated Errors) control system. The ACE control system guarantees that the actual electrolysis current produced and the count rate displayed are always correctly synchronised, regardless of changes to the electrolysis cell resistance. SpecificationsTitration method: Coulometric Karl Fischer titration Electrolysis control: Patented “ACE” control system End point detection: AC polarisation End point indication: Visual display/print out/acoustic beep Display: 40 character alphanumeric backlit LCD Measuring range (possible): 1µg – 100mg water Measuring range (typical): 1µg – 10mg water Moisture range: 1 ppm – 100% Max. sensitivity: 0.1 µg Max. titration speed: 2.0 mg per minute Max. current: 400 ma Drift compensation: Automatically controlled Start delay time: 0 - 30 minutes, user selectable End delay time: 0 - 30 minutes, user selectable Power supply: 90-264VAC, 47-63Hz Universal inputPrecision:10-100µg ±3µg, 100µg-1mg ±5µg, above 1mg ±0.5%
Print format: µg, mg/kg, ppm, % Statistics: max, mean, min values upto 99 runs Method storage: 10 user programmable methods Sample ID number: user programmable Printer: 42 character high-speed thermal printer Stirrer speed: Microprocessor controlled Dimensions: 250 x 245 x 120 mm Weight: 3 kg Language: English, Francais, Espanol, Portugues, Deutsch and Magyar Calendar/clock: Analysis time and date print out Included Accessories LDC (Low Drift Cell) glassware pack comprising twin port titration vessel, detector electrode, generator electrode, dessicant tube, molecular seive, stirrer bar, injection septa, funnel & 1ml glass syringe with luer needle. |
![]() | Ordering Information | ||||||
|
![]() | Accessories | ||||||||||||
|
Density, Relative Density (Specific Gravity), or API Gravity - Hydrometers and Thermohydrometers
Density, Relative Density (Specific Gravity), or API Gravity - Hydrometers and Thermohydrometers |
ASTM Hydrometers and Thermohydrometers For density, relative density (specific gravity) or API gravity determination of crude petroleum, liquid petroleum products and mixtures of petroleum and non-petroleum products. For density of LPG and light hydrocarbons refer toK26150. Calibrated hydrometers and thermohydrometers are available from Koehler with an ISO/IEC 17025 and ANSI/NCSL Z-540-1 Report of Calibration. When inquiring about calibrated hydrometers and thermohydrometers, please refer to the catalog number for the corresponding hydrometer or thermohydrometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01H API Gravity Hydrometer would be 251-004-01H Certified API Gravity Hydrometer. Specifications Conforming to the specifications of: ASTM E100 Applicable Test Method Standards ASTM D287, D1298, D6074, D6158; API MPMS Chapter 9.1; IP 160; ISO 3675; DIN 51757 |
| ![]() |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|