K28000 Tank Car Gauging Pole

K28000 Tank Car Gauging Pole

Features and Benefits
• Meets ASTM D1085 specifications

• 36" or 32 1/8" in length, with 1/8" graduations


Ordering Information
Catalog
Number
Construction
K28000Tank Car Gauging Pole, 36"
K28010Tank Car Gauging Pole, 32 1/8"

K27851 LPG Sample Containers

K27851 LPG Sample Containers

Test Method
All samplers conform to ASTM D4057 (formerly ASTM D270), D6074 or ASTM D1265 specifications.

Features and Benefits

• Two-valve type with 20% outage tube

• Built-in pressure relief valve

• Conforming to ASTM D1265 and GPA 2140 specifications


Click on the image to view a larger photo of the instrument.

LPG Sample Containers
Welded stainless steel cylinders for obtaining representative samples of liquefied petroleum (LP) gases. Two-valve type (1/4 IPS), with 20% outage tube and built-in pressure relief valve factory preset between 540 to 600psi (38-42 kg/cm2).


Ordering Information
Catalog
Number
Construction
K27851LPG Sample Cylinder, 150mL
K27852LPG Sample Cylinder, 300mL
K27853LPG Sample Cylinder, 500mL
K27854LPG Sample Cylinder, 1000mL
K27856LPG Sample Cylinder, 3000mL

K27600 Weighted Beaker

K27600 Weighted Beaker

Test Method
All samplers conform to ASTM D4057 (formerly ASTM D270), D6074 or ASTM D1265 specifications.

Features and Benefits

• Capacity 32 oz. (946mL)

• Choice of 3/4" or 1 1/2" (19 or 38mm) opening


Click on the image to view a larger photo of the instrument.

Weighted Beaker
For beaker sampling from tank cars, tank trucks, shore tanks, ship tanks and barge tanks. Copper or stainless steel construction with weighted bottom. Includes handle and chained cork. Takes all level samples, running samples, and top, upper, middle, lower and outlet samples. Select 3/4" (19mm) opening for light crude oils, light lubricating oils, kerosenes, gasolines, transparent gas oils, diesel fuels, and distillates, or 1 1/2" (38mm) for heavy crude and fuel oils, heavy lubricating oils and nontransparent gas oils.
Shipping Information
Shipping Weight: 
6 lbs (2.7kg)


Ordering Information
Catalog
Number
Construction
K27600Weighted Copper Beaker, with 3/4" opening
K27610Weighted Copper Beaker, with 1 1/2" opening
K27601Weighted Stainless Steel Beaker, with 3/4" opening

K27400 Drum Thief (Sampling Tube)


K27400 Drum Thief (Sampling Tube)

Test Method
All samplers conform to ASTM D4057 (formerly ASTM D270), D6074 or ASTM D1265 specifications.

Features and Benefits

• Choice of plated brass or stainless steel construction

Drum Thief (Sampling Tube)
For tube sampling from barrels and drums. Takes bottom samples or all-levels samples. Maximum sample capacity of 24 oz (710mL).
Dimensions lxdia.,in.(cm)
1.25x40 (3.2x102)

Shipping Information
Shipping Weight: 
6 lbs (2.7kg)


Click on the image to view a larger photo of the instrument.


Ordering Information
Catalog
Number
Construction
K27400Drum Thief, plated brass
K27401Drum Thief, stainless steel

K27700 Sample Thief (Bacon Bomb)

K27700 Sample Thief (Bacon Bomb)

Test Method
All samplers conform to ASTM D4057 (formerly ASTM D270), D6074 or ASTM D1265 specifications.

Features and Benefits

• Obtains bottom samples or samples from any level

• Four different capacities

• Plated brass, stainless steel or acrylic construction

• Standard Viton O-ring seal

• Optional metal-to-metal seal


Click on the image to view a larger photo of the instrument.

Sample Thief (Bacon Bomb)
Obtains samples from storage tanks, tank cars and drums. When the thief strikes the bottom of the tank, a plunger assembly opens to admit the sample. The plunger closes again when the bomb is withdrawn, forming a tight seal. Samples can be taken at any depth with the use of a secondary trip line, or extension rods may be added for obtaining samples at levels of up to 18 (46cm) off the bottom. Equipped with plunger locking cam for tight closure during transport (except for 4 oz 1 1/8" dia. model). Special models include a 4 oz (118mL) ‘pencil’ model for sampling through small diameter pipes and openings, and clear acrylic samplers with plated brass plunger and end pieces. Modified samplers can be supplied for special applications – we invite your inquiries.

Ordering Information - Sample Thief
Catalog
Number
Capacity
oz (mL)
ConstructionSealOutside Diameter (O.D.)
in. (cm.)
Overall Length
in. (cm.)
Shipping Weight
lbs (kg)
K2770032 (946)plated brassViton O-ring3 3/8 (8.6)15 5/32 (38.5)13 (5.9)
K2770132 (946)stainless steelViton O-ring3 3/8 (8.6)15 5/32 (38.5)13 (5.9)
K2779016 (473)plated brassViton O-ring2 3/4 (7)12 1/32 (30.6)9 (4.1)
K2779516 (473)plated brassMetal Seat2 3/4 (7)12 1/32 (30.6)9 (4.1)
K2779116 (473)stainless steelViton O-ring2 3/4 (7)12 1/32 (30.6)8 (3.6)
K2779216 (473)acrylicViton O-ring2 3/4 (7)12 1/32 (30.6)8 (3.6)
K277808 (237)plated brassViton O-ring2 5/16 (5.9)10 5/32 (25.8)5 (2.3)
K277858 (237)plated brassMetal Seat2 5/16 (5.9)10 5/32 (25.8)5 (2.3)
K277818 (237)stainless steelViton O-ring2 5/16 (5.9)10 5/32 (25.8)5 (2.3)
K277828 (237)acrylicViton O-ring2 5/16 (5.9)10 5/32 (25.8)5 (2.3)
K277704 (118)plated brassViton O-ring1 7/8 (4.7)9 11/16 (24.6)4 (1.8)
K277714 (118)stainless steelViton-O-ring1 7/8 (4.7)9 11/16 (24.6)4 (1.8)
K277724 (118)plexiglassBuna N O-ring1 5/8 (4.01)9 11/16 (24.6)3 (1.4)
K277604 (118)plated brassViton O-ring1 1/8 (2.8)13 1/4 (33.7)3 (1.4)
K277614 (118)stainless steelViton O-ring1 1/8 (2.8)13 1/4 (33.7)3 (1.4)
K277624 (118)acrylicViton O-ring1 1/8 (2.8)13 1/4 (33.7)3 (1.4)

K277-EXT Sample Thief Extension Rods

Sample Thief Extension Rods
Installs in sample thief plunger assembly. Stainless steel with threaded end.

Ordering Information - Sample Thief Extension Rods
Catalog
Number
Length
in. (cm)
Application
K277-EXT11 (2.5)32, 16 and 8 oz models
K277-EXT22 (5.1)
K277-EXT33 (7.6)
K277-EXT66 (15.2)
K277-EXT1212 (30.5)
K277-EXT1818 (45.7)
K277C-EXT11 (2.5)4 oz models
K277C-EXT22 (5.1)
K277C-EXT33 (7.6)
K277C-EXT66 (15.2)
K277C-EXT1212 (30.5)
K277C-EXT1818 (45.7)

K27800 All-Levels Sample Thief

All-Levels Sample Thief 
Similar to the standard 16 oz (473mL) Sample Thief (Bacon Bomb), but equipped with an adjustable needle valve opening instead of a plunger to control rate of flow during ‘all-levels’ and ‘running’ sampling from storage tanks. Plated brass construction.

Ordering Information - All-Levels Sample Thief
Catalog
Number
Product Description
K27800All-Levels Sample Thief

K27900 Adjustable-Level Sample Thief

Adjustable-Level Sample Thief
Similar to the standard 16 oz (473mL) Sample Thief (Bacon Bomb), but equipped with an adjustable needle valve opening instead of a plunger to control rate of flow during ‘all-levels’ and ‘running’ sampling from storage tanks. Plated brass construction.


Ordering Information - Adjustable-Level Sample Thief
Catalog
Number
Product Description
K27900Adjustable-Level Sample Thief

K90375 Volumetric Karl Fischer Titrator

K90375 Volumetric Karl Fischer Titrator

Test Method
Determines higher concentrations of water in a wide range of liquid and powder samples. Used for assessing water content in petroleum and
petrochemical products including oils, gasolines, solvents, and fluids as well as other products in the Pharmaceutical, Cosmetic, Automotive, Food/Beverage and Agriculture industries.

Volumetric Karl Fischer Titrator

• Intuitive keypad and function guide display
• Automatic and periodic elimination of bubbles which can form in the liquid circuit
• Automatic drift monitoring and compensation
• Flexible-can be used with different reagent brands
• 2 x 5mL syringes- one for the KF reagent and the other for automatic dosing of standard for the titre (second syringe can also be used for different factor reagent or special reagents for ketones, amines, etc.) Syringe volume dispensed in 40,000 steps
• 2 x built in pumps- one for dispensing the solvent and other for emptying the vessel
• 2 x electrovalves- fitted to top of each syringe, control flow direction of solvent and reagents
• Automatic rest cycle (stand-by mode) if not used for 15 minutes
• Programmable- several easy to use programs for titration and standardization
• Results expressed in ppm, mg/l, %, etc.
• Connects to external PC keyboard for easy text and sample information data entry
• Connects to different types of printers, PC’s and balances
• Data Logger- automatic data storage of last 55 analysis results


The AKF6000 Compact Volumetric Karl Fischer Titrator is a versatile instrument capable of conforming to a multitude of Standard Test Methods. This fully programmable titrator offers several easy to use programs for titration and standardization. 4 standardization methods can be selected by the user. The AKF6000 then determines the reagent factor and automatically stores it in the titration programs. The AKF6000 is equipped with 2 Peristaltic Pumps capable of automatically dispensing a required volume of solvent into the
titration vessel as well as emptying the contents of the vessel directly into a waste container. The built in Drift Monitoring System automatically determines the vessel drift after a titration has concluded. This drift value is then deducted from a later titration. The AKF6000 will prompt the user if the measured drift value is greater than the programmed limit value.



Click on the image to view a larger photo of the instrument.

SpecificationsConforms to the specifications of:
ASTM D789, D803, D890, D1123, D1152, D1193, D1348, D1364, D1568, D1631, D2072, D2575, D3401, D4017, D4377, D4672, D5460, D5530, E180, E203
Non-volatile memory: Up to 10 titration programs, Clock/calendar,
Header texts: 2 lines x 40 characters
Name of up to 4 operators
Program comments: 8 lines x 40 characters
Up to 55 results stored in Data Logger
Languages: English Spanish, French, Latin
Display: Graphic backlit LCD, 128 x 64 dots
Keypad: Membrane, 7 keys, guaranteed up to 6 million strokes per key
Material: PET with protective treatment
Measuring ranges: From 0.1 mg up to 100% water
Syringe volume: Standard syringe 5mL
Resolution: 1/40000 of syringe volume
Dispensing accuracy: (as relative error) ≤0.2% for volumes higher than 10% of the syringe
Dispensing reproducibility: ±0.1% for volumes higher than 10% of the syringe
Liquid contact materials: Syringe: borosilicate glass and PTFE
Electovalve: PTFE and KEL-F
Tubes: PTFE
Inputs and outputs: Polarized electrode, BNC connector
For external keyboard, miniDIN connector
RS232C bidirectional for PC or printer, telephone connector
RS232C for balance, telephone connector
Stirrer control: On/Off and speed, RCA connector
Electrical Requirements: 90-264VAC, 47-63 Hz, 24V DC
Electrical safety: Meets EC, EN61010
EMC: Meets EC, EN 50081-2 and EN 50082-2
Permitted temperatures: Operating: 15-40°C
Storage: -10-50°C
≤≥<80%, relative humidity, non-condensing
Enclosure: ABS and enameled steel

Included Accessories
Power supply 90-264VAC, 47-63Hz, 24 V DC
TLL SL syringe, 5mL (2)
Burette inlet tube with bottle cap, DIN 45 screw (2)
Burette outlet tube with antidiffuser device (2)
Drier cartridge with molecular sieve (5)
Inlet pump tube (for solvent dispensing) with bottle cap DIN 45 screw
Inlet & Outlet tubes with conical adapter (2)
Outlet pump tube with bottle cap DIN 45 screw
Support for electrode & tubes with magnetic stirrer and vessel
Double platinum electrode
Electrode cable with BNC connector
Pack (10) white O-rings

Dimensions wxdxh,in.(cm)
5-1/4x6-1/2x12(130x160x300)
Net Weight: 9 lbs. (4 kg)


Ordering Information
Catalog
Number
Product Description
K90375
AKF6000 Compact Volumetric Karl Fischer Titrator

Accessories
Catalog
Number
Product Description
K90375-1
Thermal printer CT-S280, 40 columns
K90375-2
Dot matrix printer
K90375-3
Standard PC keyboard
K90375-4
Software kit for communication between KF Titrator and PC, includes CD with software and cable

K90365 Coulometric Karl Fischer Titrator

K90365 Coulometric Karl Fischer Titrator

Test Method
Determines low concentrations of water in a wide range of liquid, gas and powder samples. Used for assessing water content in petroleum and
petrochemical products including oils, gasolines, solvents, and fluids as well as other products such as pharmaceuticals and cosmetics.

• ASTM D 1533, D4928, D6304, IP 386, IP 438, API MPMS Chap. 10.9, BS 60814, ISO 10101-3, ISO 10337, ISO 12937
• Simple operation
• Multi-language display and print out
• Integral high-speed thermal printer
• Small footprint
• Automatic Compensation of Errors


Click on the image to view a larger photo of the instrument.

K90365 Coulometric Karl Fischer Titrator
The K90365 offers new standards in versatility and ease of operation. Providing fast, accurate and reproducible determinations of water content in liquids, gases and powders. This easy to use titrator incorporates many state-of-the-art features. Designed to be equally suitable for meeting the routine needs of the Quality Control laboratory or the more demanding and varied requirements of research applications. Hard copies of results are provided by the built in high-speed thermal printer, along with statistics, data input parameters, sample ID numbers and time/date of analysis. At the heart of the K90365 is state of the art ACE (Automatically Compensated Errors) control system. The ACE control system guarantees that the actual electrolysis current produced and the count rate displayed are always correctly synchronised, regardless of changes to the electrolysis cell resistance.

SpecificationsTitration method: Coulometric Karl Fischer titration
Electrolysis control: Patented “ACE” control system
End point detection: AC polarisation
End point indication: Visual display/print out/acoustic beep
Display: 40 character alphanumeric backlit LCD
Measuring range (possible): 1µg – 100mg water
Measuring range (typical): 1µg – 10mg water
Moisture range: 1 ppm – 100%
Max. sensitivity: 0.1 µg
Max. titration speed: 2.0 mg per minute
Max. current: 400 ma
Drift compensation: Automatically controlled
Start delay time: 0 - 30 minutes, user selectable
End delay time: 0 - 30 minutes, user selectable
Power supply: 90-264VAC, 47-63Hz Universal input
Precision:10-100µg ±3µg, 100µg-1mg ±5µg, above 1mg ±0.5%
Calculation modes:Weight/weight, user programmable
 Weight/dilution ratio, user programmable
 Volume/density, user programmable
 Volume/volume, user programmable
Display format: µg, mg/kg, ppm, %
Print format: µg, mg/kg, ppm, %
Statistics: max, mean, min values upto 99 runs
Method storage: 10 user programmable methods
Sample ID number: user programmable
Printer: 42 character high-speed thermal printer
Stirrer speed: Microprocessor controlled
Dimensions: 250 x 245 x 120 mm
Weight: 3 kg
Language: English, Francais, Espanol, Portugues, Deutsch and Magyar
Calendar/clock: Analysis time and date print out

Included Accessories
LDC (Low Drift Cell) glassware pack comprising twin port titration vessel,
detector electrode, generator electrode, dessicant tube, molecular seive, stirrer bar, injection septa, funnel & 1ml glass syringe with luer needle.


Ordering Information
Catalog
Number
Product Description
Electrical Requirements
K90365
Compact Coulometric Karl Fischer Titrator
115-240V 50/60Hz


Accessories
Catalog
Number
Product Description
K90365-7
Gas Analysis Kit (comprises gas inlet, gas outlet, seal ring & cap)
K90365-8
Carry Case
K90365-20Reagents (Pack of 8 x 100ml anode reagent, 8 x 5ml cathode reagent)
K90365-35
Water Standard, 0.1 mg/ml, 5ml, pk/10
K90365-36Water Standard, 1.0 mg/ml, 5ml, pk/10

Density, Relative Density (Specific Gravity), or API Gravity - Hydrometers and Thermohydrometers

Density, Relative Density (Specific Gravity), or API Gravity - Hydrometers and Thermohydrometers

ASTM Hydrometers and Thermohydrometers
For density, relative density (specific gravity) or API gravity determination of crude petroleum, liquid petroleum products and mixtures of petroleum and non-petroleum products. For density of LPG and light hydrocarbons refer toK26150.

Calibrated hydrometers and thermohydrometers are available from Koehler with an ISO/IEC 17025 and ANSI/NCSL Z-540-1 Report of Calibration.

When inquiring about calibrated hydrometers and thermohydrometers, please refer to the catalog number for the corresponding hydrometer or thermohydrometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01H API Gravity Hydrometer would be 251-004-01H Certified API Gravity Hydrometer.

Specifications
Conforming to the specifications of: ASTM E100

Applicable Test Method Standards
ASTM D287, D1298, D6074, D6158; API MPMS Chapter 9.1; IP 160; ISO 3675; DIN 51757

API Gravity Hydrometers
Standard temperature 60°F, subdivisions 0.1° API, length 330mm
Catalog
Number
ASTM Hydrometer No.Nominal API GravityRange, deg.
251-000-01H1H–1 to +11
251-000-02H2H9 to 21
251-000-03H3H19 to 31
251-000-04H4H29 to 41
251-000-05H5H39 to 51
251-000-06H6H49 to 61
251-000-07H7H59 to 71
251-000-08H8H69 to 81
251-000-09H9H79 to 91
251-000-10H10H89 to 101

Specific Gravity Hydrometers
Standard temperature 60/60°F, subdivisions 0.0005, length 330mm
Catalog
Number
ASTM Hydrometer No.Nominal Specific Gravity Range
251-000-82H82H0.650 to 0.700
251-000-83H83H0.700 to 0.750
251-000-84H84H0.750 to 0.800
251-000-85H85H0.800 to 0.850
251-000-86H86H0.850 to 0.900
251-000-87H87H0.900 to 0.950
251-000-88H88H0.950 to 1.000
251-000-89H89H1.000 to 1.050
251-000-90H90H1.050 to 1.100

API Gravity Hydrometers
Standard temperature 60°F, subdivisions, 0.1° API, length 330mm
Catalog
Number
ASTM Hydrometer No.Nominal API Gravity Range, deg.
251-000-21H21H0 to 6
251-000-22H22H5 to 11
251-000-23H23H10 to 16
251-000-24H24H15 to 21
251-000-25H25H20 to 26
251-000-26H26H25 to 31
251-000-27H27H30 to 36
251-000-28H28H35 to 41
251-000-29H29H40 to 46
251-000-30H30H45 to 51
251-000-31H31H50 to 56
251-000-32H32H55 to 61
251-000-33H33H60 to 66
251-000-34H34H65 to 71
251-000-35H35H70 to 76
251-000-36H36H75 to 81
251-000-37H37H80 to 86
251-000-38H38H85 to 91
251-000-39H39H90 to 96
251-000-40H40H95 to 101
API Gravity Thermohydrometers - Thermometer in Body
Standard temperature 60°F, subdivisions 0.1° API, length 380mm, thermometer scale °F 0-150 (designation L), 30 to 180 (designation M), 60 to 220 (designation H)
Catalog
Number
ASTM Thermohydrometer No.Nominal API Gravity Range, deg.
251-000-51HH51HH–1 to 11
251-000-51HL51HL–1 to 11
251-000-52HH52HH9 to 21
251-000-52HL52HL9 to 21
251-000-53HM53HM19 to 31
251-000-53HL53HL19 to 31
251-000-54HM54HM29 to 41
251-000-54HL54HL29 to 41
251-000-55HL55HL39 to 51
251-000-56HL56HL49 to 61
251-000-57HL57HL59 to 71
251-000-58HL58HL69 to 81
251-000-59HL59HL79 to 91
251-000-60HL60HL89 to 101
API Gravity Thermohydrometers Thermometer in Stem
Standard temperature 60°F, subdivisions 0.1° API, length 380mm, temperature scale °F 30-220
Catalog
Number
ASTM Thermohydrometer No.Nominal API Gravity Range, deg.
251-000-71H71H–1 to 11
251-000-72H72H9 to 21
251-000-73H73H19 to 31
251-000-74H74H29 to 41
Specific Gravity Hydrometers
Standard temperature 60/60°F, subdivisions 0.001 length 260mm
Catalog
Number
ASTM Hydrometer No.Nominal Specific Gravity Range
251-000-102H102H0.650 to 0.700
251-000-103H103H0.700 to 0.750
251-000-104H104H0.750 to 0.800
251-000-105H105H0.800 to 0.850
251-000-106H106H0.850 to 0.900
251-000-107H107H0.900 to 0.950
251-000-108H108H0.950 to 1.000
251-000-125H125H1.000 to 1.050
251-000-126H126H1.050 to 1.100
251-000-127H127H1.100 to 1.150
251-000-128H128H1.150 to 1.200
251-000-129H129H1.200 to 1.250
251-000-130H130H1.250 to 1.300
251-000-131H131H1.300 to 1.350
251-000-132H132H1.350 to 1.400
251-000-133H133H1.400 to 1.450
251-000-134H134H1.450 to 1.500
251-000-135H135H1.500 to 1.550
251-000-136H136H1.550 to 1.600
251-000-137H137H1.600 to 1.650
251-000-138H138H1.650 to 1.700
251-000-139H139H1.700 to 1.750
251-000-140H140H1.750 to 1.800
251-000-141H141H1.800 to 1.850
ASTM Metric Thermohydrometers
Standard temperature 15°C, subdivisions 0.5kg/m3, length 380mm, thermometer scale °C: –20 to +65 (designation L), 0 to 85 (designation M), 20 to 105 (designation H)
Catalog
Number
ASTM Thermohydrometer No.Density, Range kg/m3
251-000-300HL300HL600 to 650
251-000-301HL301HL650 to 700
251-000-302HL302HL700 to 750
251-000-302HM302HM700 to 750
251-000-303HL303HL750 to 800
251-000-303HM303HM750 to 800
251-000-304HL304HL800 to 850
251-000-304HM304HM800 to 850
251-000-305HL305HL850 to 900
251-000-305HM305HM850 to 900
251-000-306HL306HL900 to 950
251-000-306HM306HM900 to 950
251-000-307HL307HL950 to 1000
251-000-307HH307HH950 to 1000
251-000-308HH308HH1000 to 1050
251-000-308HL308HL1000 to 1050
251-000-309HH309HH1050 to 1100
251-000-309HL309HL1050 to 1100