Sunday 14 February 2016

K34700 BV4000 Brookfield Viscosity Air Bath

K34700 BV4000 Brookfield Viscosity Air Bath

Test Method
Determines the low temperature, low shear rate viscosities of gear oils, automatic transmission fluids, hydraulic oils and other fluid lubricants by use of the Brookfield viscometer.

Features and Benefits
• 
Conforms to ASTM D2983 and related specifications

• 
Mechanically refrigerated with digital temperature control

• 
Operating range to –50°C

• 
Sixteen sample capacity


Click on the image to view a larger photo of the instrument.

BV4000 Brookfield Viscosity Air BathMechanically refrigerated cold cabinet prepares samples for Brookfield viscosity determinations on petroleum lubricants. A built-in turntable rotates the samples at 4 RPM per specifications. Cooling system maintains cabinet temperature within ±0.1°C at temperatures as low as –50°C. Cabinet temperature is displayed in digital format on the front panel. Cabinet accommodates sixteen (16) sample cells with cell carriers. Includes insulated cover.

SpecificationsConforms to:
ASTM D2983; IP 267 Method A; ISO 9262; CEC-L-18A

Capacity: Sixteen (16) sample cells with cell carriers

Temperature Range: –10°C to –50°C

Temperature Control Accuracy: ±0.1°C

Sample Rotation: 4 RPM
Electrical Requirements
115V, 60Hz, Single Phase, 16A
220-240V, 50 or 60Hz, Single Phase, 12A

Dimensions lxwxh,in.(cm)
36x28x43 (91x71x109)
Net Weight: 315 lbs (143kg)

Shipping Information
Shipping Weight: 380 lbs (172kg)
Dimensions: 39 Cu. ft.

Ordering Information
Catalog
Number
Product Description
Electrical Requirements
K34700
BV4000 Brookfield Viscosity Air Bath
115V, 60Hz, 16A
K34701BV4000 Brookfield Viscosity Air Bath220-240V, 50Hz, 12A
K34702
BV4000 Brookfield Viscosity Air Bath
220-240V, 60Hz, 12A


Accessories
Catalog
Number
Product DescriptionAdditional Information
K34750Brookfield Digital Viscometer115V, 60Hz
K34751Brookfield Digital Viscometer220-240V, 50Hz
K34752Brookfield Digital Viscometer220-240V, 60Hz
K34760Brookfield Programmable Viscometer115V, 60Hz
K34761Brookfield Programmable Viscometer220-240V, 50Hz
K34762Brookfield Programmable Viscometer220-240V, 60Hz
K34706Insulated Spindle No.4
K34704Non-Insulated Spindle No.4
K34707Cell Stopper
K34708Insulated Cell Carrier
K34709Test Cell - Round Bottompack of 12
K34770Test Cell - Flat Bottompack of 12
250-000-122CASTM 122C/IP94C ThermometerRange –45 to –35°C
250-000-123CASTM 123C/IP95C ThermometerRange –35 to –25°C
250-000-124CASTM 124C/IP96C ThermometerRange –25 to –15°C
250-000-125CASTM 125C/IP97C ThermometerRange –15 to –5°C
355-005-027Viscosity Standard N27BViscosities in centipoise at –40, –30, –20, –15, –10, 0°F
355-005-115Viscosity Standard N115BViscosity in centipoise at –20, –15, –10, 0, +10, +20°F